Minimizing coliform and Escherichia coli bacteria in clean water through a chlorine diffuser method combined with black sand

DOI: https://doi.org/10.33024/minh.v7i10.553

Authors

  • Eka Nurul Fathonah Universitas Muhammadiyah Surakarta
  • Rezania Asyfiradayati Universitas Muhammadiyah Surakarta

Chlorine Diffuser Coliform E-Coli

Abstract

Background: Indonesia's 2016 health profile shows that the percentage of households with access to drinking water and potable water in Central Java Province is 75.88%, leaving 24.2% of the population without adequate drinking water sources. High concentrations of total Coliform are an indicator of pathogenic contamination that can lead to the spread of waterborne diseases. Contamination from E. coli and coliform bacteria in clean water sources can cause diarrhea if consumed.

Purpose: To assess the effectiveness of the chlorine diffuser method combined with black sand in reducing Coliform and Escherichia coli levels in clean water.

Method: A quantitative descriptive approach with a quasi-experimental design. Samples were collected four times over a ten-day period, with bacterial levels measured before and after treatment at intervals of 30 minutes, 45 minutes, and 60 minutes. The study utilized a chlorine diffuser as the primary research instrument. Data collection methods included direct observation and the compilation of both primary and secondary data. Laboratory testing of the samples was performed using the compact dry method, followed by univariate analysis to evaluate the effectiveness of the chlorine diffuser in reducing coliform bacteria in groundwater wells.

Results: Univariate analysis showed that before treatment, the coliform bacteria level was 60 CFU/100 ml. After treatment, the levels were 40 CFU/100 ml after 30 minutes, 45 CFU/100 ml after 45 minutes, and 40 CFU/100 ml after 60 minutes of contact time. For E. coli, the bacteria level before treatment was 3 CFU/100 ml. After treatment, it was 0 CFU/100 ml with 30 minutes of contact, 1 CFU/100 ml with 45 minutes of contact, and 1 CFU/100 ml with 60 minutes of contact. Bivariate analysis showed a significant difference in Coliform levels based on treatment duration, with a significance value of 0.014. However, no significant difference was observed in E. coli levels, with a significance value of 0.168.

Conclusion: The combination of the chlorine diffuser method and black sand effectively reduced coliform bacteria levels to meet environmental health standards. However, this method was less effective in eliminating Escherichia coli within the same treatment duration.

Downloads

Download data is not yet available.

References

Afifah, F. (2019). Uji bakteriologis coliform dan Escherichia coli pada air tanah bebas.

Alfin, E., Rahmatulloh, R., & Suendarti, M. (2022). Infrastruktur Air Dan Tantangan Di Indonesia. SENTRI: Jurnal Riset Ilmiah, 1(2), 382-391.

Asyfiradayati, R., Sukmawati, D., Sriwahyuni, E., & Hadiana, F. (2023). Uji Bakteriologis Air Bersih Pemukiman Sekitar Mata Air Cokro Desa Krajan Kabupaten Klaten. Jurnal Ners, 7(2), 1407-1412.

Bonkoungou, I. J. O., Somda, N. S., Traoré, O., Zoma, S., Garba, Z., Drabo, K. M., & Barro, N. (2021). Detection of diarrheagenic Escherichia coli in human diarrheic stool and drinking water samples in Ouagadougou, Burkina Faso. African Journal of Infectious Diseases, 15(1), 53-58.

De Luca, V., Carginale, V., Supuran, C. T., & Capasso, C. (2022). The gram-negative bacterium Escherichia coli as a model for testing the effect of carbonic anhydrase inhibition on bacterial growth. Journal of Enzyme Inhibition and Medicinal Chemistry, 37(1), 2092-2098.

Efendy, I., & Syamsul, D. (2019). Faktor Yang Berhubungan Tingkat Konsumsi Air Bersih Pada Rumah Tangga Di Kecamatan Peudada Kabupaten Bireun. Jurnal Biology Education, 7(2).

Fibryanto, E., & Santoso, L. (2023). Mouthwashes: a review on its efficacy in preventing dental caries. Jurnal Kedokteran Gigi Terpadu, 5(1).

Ganefati, S. P., Sanjtoko, H., Sudaryanto, S., Sutedjo, S., Eko, S., Haryono, H., & Sugianto, S. (2023). Upaya Pengendalian Penyakit Menular Lapas Kelas II B Sleman Melalui Penyuluhan Kesehatan, Desinfeksi Kuman Udara Ruangan di Blok Tahanan, dan Penyehatan Air. J-ABDI: Jurnal Pengabdian kepada Masyarakat, 3(6), 1177-1186.

Gufran, M., & Mawardi, M. (2019). Dampak pembuangan limbah domestik terhadap pencemaran air tanah di Kabupaten Pidie Jaya. Jurnal Serambi Engineering, 4(1), 416-425.

Habibi, N. A., Utami, C. T., Mulyana, M., & Amelia, R. R. (2019). Efektifitas dan efisiensi penggunaan klorinator sebagai sarana pelarut disinfektan di Usaha Kecil dan Menengah (UKM). JST (Jurnal Sains Terapan), 5(1), 54-59.

Kartini, J., Kasman, R. A., Arsyad, R., & Ismail, H. (2024). Sosialisasi Kualitas Air Wisata Pantai: Dampak Pencemaran Bakteri Coliform dan Eschericia Coli. Ininnawa: Jurnal Pengabdian Masyarakat, 2(1), 113-118.

Khairunnida, G. R., Rusmini, H., Maharyuni, E., & Warganegara, E. (2020). Identifikasi Escherichia coli Penyebab Waterborne Disease pada Air Mimun Kemasan dan Air Mimunm Isi Ulang. Jurnal Ilmiah Kesehatan Sandi Husada, 9(2), 634-639.

Kuswanto, S., Yuniarno, S., & Hastawati, I. (2021). Making Chlorine Diffuser In Reducing Coliform Numbers In The Wells. Kesmas Indonesia, 13(2), 168-181.

Luqman, M., & Al-Ansari, T. (2021). A novel integrated wastewater recovery, clean water production and air-conditioning system. Energy Conversion and Management, 244, 114525.

Maliangkay, K. S., Erinaputri, N., Salsabila, N., & Setiawati, M. E. (2022). Analisis Hubungan Kondisi Ekonomi Masyarakat Terhadap Pemakaian Air Domestik. Jurnal Kesehatan Tambusai, 3(4).

Mangkurat, W., Nurdiana, E., & Budianto, A. (2019, September). Penurunan Kadar Amonia, Nitrit, dan Nitrat pada Air Sungai Menggunakan Karbon Aktif sebagai Solusi Efisiensi Chlorine. In Prosiding Seminar Nasional Sains dan Teknologi Terapan (Vol. 1, No. 1, pp. 279-284).

Marchesi, I., Paduano, S., Frezza, G., Sircana, L., Vecchi, E., Zuccarello, P., & Bargellini, A. (2020). Safety and effectiveness of monochloramine treatment for disinfecting hospital water networks. International journal of environmental research and public health, 17(17), 6116.

Mariyam, D., Devina, F., Wulandari, P., Nursafitri, E., & Syahriansyah, A. (2023). Rahasia Molekul Unsur yang terdapat dalam Air Putih Bagi Tubuh Manusia dalam Pandangan Islam. Religion: Jurnal Agama, Sosial, Dan Budaya, 1(3), 96-109.

Maulidia, Z., Mirwan, M., & Aulidia, S. (2023). Pengelolaan Air Bersih di RS X Surabaya. Nusantara Hasana Journal, 2(8), 36-41.

Mulyati, S. A., Azizah, M., Srikandi, S., Maidaswar, M., & Atikah, N. (2022). The effectiveness of chlorine tablets to reducing coliform in wastewater treatment plant. Jurnal Sains Natural, 12, 10-16.

Nabih, F. N., Takwanto, A., & Rahayu, M. (2021). Pengaruh Konsentrasi Ozon Terhadap Nilai Ph Dan Total Dissolve Solid (Tds) Produk Air Minum Dalam Kemasan (Amdk). Distilat: Jurnal Teknologi Separasi, 7(2), 347-352.

Nowicki, S., Delaurent, Z. R., de Villiers, E. P., Githinji, G., & Charles, K. J. (2021). The utility of Escherichia coli as a contamination indicator for rural drinking water: Evidence from whole genome sequencing. PLoS One, 16(1), e0245910.

Pambudi, L., Ismail, K. M., & Sudjanto, H. (2019). Rancangan Sistem Otomatis Chlorinator Pada Distribusi Air Bersih Di Bandar Udara International Soekarno-Hatta. Langit Biru: Jurnal Ilmiah Aviasi, 12(3), 127-136.

Patmawati, P., & Sukmawati, S. (2017). Pengaruh Dosis Klorin terhadap Total Coliform Wai Sauq Bantaran Sungai Mandar. Higiene, 6(1), 1–4

Patmawati, P., & Sukmawati, S. (2019). Chlorinediffuser sebagai metode menurunkan total coliform Wai Sauq bantaran Sungai Mandar. J-KESMAS: Jurnal Kesehatan Masyarakat, 5(2), 124-137.

Patmawati, P., & Sukmawati, S. (2020). Menurunkan Bakteri Total Coliform Wai Sauq Bantaran Sungai Mandar Dengan Chlorine Diffuser. HIGIENE: Jurnal Kesehatan Lingkungan, 5(2), 106-112.

Porusia, M., Asyfiradayati, R., Putri, S. R. S., & Dwinanda, S. S. (2022, April). Comparison of Microbiological Quality of Well Water and Contaminated River Water in Open Defecation Area. In International Conference on Health and Well-Being (ICHWB 2021) (pp. 95-100). Atlantis Press.

Pratama, I. N., & Hidayatullah, H. (2023). Strategi Dan Kebijakan Pemerintah Dalam Mengatasi Masalah Pencemaran Air Tanah. Journal of Environmental Policy and Technology, 1(2), 105-112.

Restiyani, A. A. (2019). Analisis Kandungan Bakteri Coliform dan Escherichia coli Pada Air Minum Dalam kemasan dan Air Minum Isi Ulang di Kecamatan Sukarame Bandar Lampung. Universitas Raden Intan Lampung

Rosdiana, D., Hastiaty, I. A., Hartomy, E., Kango, I., Simbolon, P. T., Pradapaningrum, P. G., & Paramasatya, A. (2023). Kontaminasi kimia dan biologi pada air dan udara dengan ARKM: analisis risiko kesehatan masyarakat. Public Health Risk Assesment Journal, 1(1).

Saputri, E. T., & Efendy, M. (2020). Kepadatan bakteri coliform sebagai indikator pencemaran biologis di perairan pesisir sepuluh Kabupaten Bangkalan. Juvenil: Jurnal Ilmiah Kelautan dan Perikanan, 1(2), 243-249.

Sitaba, T. F. N., & Nurlinda, A. (2022). Identifikasi Kandungan Escherichia coli pada Es Dawet di Jalan Urip Sumohardjo Kota Makassar. Window of Public Health Journal, 3(1), 96-101.

Sulistiyawati, I. (2019). Kuantitas total bakteri coliform pada instalasi pengolahan limbah cair medis laboratorium klinik. Jurnal Ilmiah Universitas Batanghari Jambi, 19(3), 675-677.

Utami, F. (2020). Metode Most Probable Number (MPN) Sebagai Dasar Uji Kualitas Air Sungai Rengganis Dan Pantai Timur Pangandaran Dari Cemaran Coliform dan Escherichia coli. Jurnal Kesehatan Bakti Tunas Husada: Jurnal Ilmu-ilmu Keperawatan, Analis Kesehatan dan Farmasi, 20(1), 21-30.

Downloads

Published

2024-12-31

How to Cite

Minimizing coliform and Escherichia coli bacteria in clean water through a chlorine diffuser method combined with black sand. (2024). MIN, 7(10), 1201-1208. https://doi.org/10.33024/minh.v7i10.553